buttonHome Page.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
buttonThe Firm.bmp (12054 bytes)
button blank.bmp (12054 bytes)
buttonReligious Buildings.bmp (12054 bytes)
button blank.bmp (12054 bytes)
buttonFinancial Buildings.bmp (12054 bytes)
button blank.bmp (12054 bytes)
buttonOther Buildings.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
buttonChurch Design Resources.bmp (12054 bytes)
buttonSelecting.bmp (12054 bytes)
buttonServices.bmp (12054 bytes)
buttonProjSteps.bmp (12054 bytes)
buttonSteering.bmp (12054 bytes)
buttonPreparing_a_Budget.bmp (12054 bytes)
buttonSiteselect.bmp (12054 bytes)
buttonRelocating.bmp (12054 bytes)
buttonExterior.bmp (12054 bytes)
buttonInterior.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)
button blank.bmp (12054 bytes)

Steps in a Building Project
By Robert C. Foreman, Architect
A Guideline through the Building Process.

Download this page as a PDF file

1.    Identify property and building inadequacies.

a.   List general inadequacies.
b.   Review list of inadequacies with key program leaders.

2.   Secure outside help.

a.   Request help from denomination, association or diocese.
b.   Obtain published guidebooks for help in organizing and planning.

3.   Secure church action to appoint a Survey, Planning and Building Committee.

a.   Report property and building inadequacies to the church.
b.   Ask for approval to structure a Survey, Planning and Building
      Committee to begin a study that is directed at the church taking
      actions to meet property and building needs.

4.   Organize and educate committee

a.   Appoint building project steering committee (7 to 10 members).
b.   Appoint three to five or more members on each subcommittee.
c.   Educate committee on process using guidebooks or materials
      obtained from denomination.

5.   Explore community needs to discover church opportunities.

a.   Survey community.
b.   Determine specific needs of persons in the community.
c.   Define church’s mission.
d.   Determine number of persons who might be reached in each
      program.
e.   Begin site selection process if property is not owned.

6.   Select an Architect

a.   Gather list of architects
b.   Interview, review experience, call references.
c.   Select Architect.

7.   Develop a comprehensive program

a.   Define and prepare a written statement of programs to be provided  by the church.
b.   Ascertain number of people for which space will be provided in each church program.
c.    Architect to participate in program development.

8.   Site selection

a.   Evaluate suitability and location of existing property.
b.   If moving or acquiring property for first unit, determine general
      location where church needs to be.
c.   Determine amount of property needed.  Minimum 5 acre site.
      Allow 100 people per usable acre.
d.   Architect should participate in site selection and evaluation.
      Do not purchase the property until it is certain that it will be
      adequate for church needs.

9.    Topographic / Boundary Survey of Site

10.  Architect authorized to prepare Master Site Plan.

11.   Prepare financial plan

a.   Review past and present financial performance.
b.   Make initial contact with sources of help regarding a fund-raising
      campaign.
c.   Project amount of money to be raised in an intensive fund-raising
      campaign.
d.   Investigate sources for borrowing funds, and potential amounts
      available.
e.   Secure tentative loan commitments.
f.    Determine maximum funds which can be made available for a
      building project.

12.    Complete the property purchase, if not already owned.

13.    Architect or church to secure services of a civil engineer.

14.    Architect authorized to prepare Schematic Building Plans.

15.    Church to begin contractor selection.

16.    Master Site Plan to be submitted to local planning and zoning, if necessary.

17.    Report to church and secure church decision/begin fund raising

a.   Report findings and recommendations to church.
        i.     Program needs for which space will be provided.
        ii.    Site Master Plan and Schematic Building Design.
        iii.   Estimated project cost.
        iv.   Means and source of financing project.
        v.    Growth and other results anticipated.
b.   Secure church action on:
        i.    Type and amount of space to be constructed.
        ii.   Acquisition of any properties needed.
        iii.  Proceeding with final drawings.
        iv.  Financing plan for the project.
        v.   Begin fund raising.
        vi.  Approval of Contractor selection.

18.   Architect and engineers to proceed with design drawings for the building
         and site.

a.   Authorize architect to prepare floor plans and cost estimates.
b.   Present plans and cost estimates to church for approval.
c.  Contractor to provide design and cost input.

19.   Architect and Engineers ro proceed with final detailed Construction
        Documents

a.    Architect and Engineers to incorporate church design input
b.    Contractor to provide design and cost input.
c.    Report to church when plans are completed and approved
       by committee.

20.    Submit plans to various local and state authorities for review and approval.

a.   Local City / County Development Department and Building
      Department.
b.   State Fire Marshal.
c.   Architect to meet with local and state plan review personnel to
      coordinate plan review and approval process and satisfy plan
      review comments.

21.    Contractor to prepare final pricing or job is put out for bids.

22.    Architect to obtain final approval of plans from local and state authorities.

23.    Church to finalize financing arrangements.

24.    Church to approve construction price - sign contract - provide
          notice to proceed to general Contractor.

25.    Contractor to obtain building permit and begin construction.  This time
          is 6 to 12 months for most projects.

26.    Begin organizational enlargement and leadership training simultaneously
          with beginning construction.

a.   Enlist new workers for enlarged organization.
b.   Inaugurate an aggressive and intensive training program for
      present and new workers.
c.   Design a "saturation" visitation program to be implemented
      immediately prior to occupancy of the new building.

27.    Church to order furniture and other equipment not included on 
          General Contract (sound system, pews, kitchen equipment, operable 
          walls, etc.).

28.    Church to anticipate completion date- schedule and plan for
          dedication service six to ten weeks after occupancy.

29.    Construction substantially complete.  Begin to furnish and equip the
          building.  Heating / cooling system must be operational.  Inspect 
          furniture and test equipment.

30.    Occupy and begin using facility only after all work is complete, building
          has been declare complete by the architect and local authorities have
          granted "certificate of occupancy."

31.   One to two month "shakedown" period begins.

a.   Defects are found and corrected.
b.   Adjustments are made to air conditioning, electrical systems
      sound systems and "bugs" worked out.
c.   Final payment made to contractor

32.    Dedication Service - should never be planned for the first Sunday
         of Occupancy to allow proper planning, last minute work and final
         adjustments.

33.    Evaluation at the one year anniversary of completion to make a list
          of items that need attention prior to expiration of the one year
         warranty period.